Spacer
 
Spacer

HDI Microvia Constructions and Dimensions

 

Revision 2, May 2001

 

GPV offers two kinds of HDI constructions, laser drilled or mechanical drilled blind via holes, both types combined with buried and through holes.

 

 

Preferred producibility is volume capability, reduced producibility indicate reduced volume and/or higher cost and may be limited to certain constructions. Please contact our sales department for more information when using reduced producibility.

 
 

 

RCC FOIL

LASER DRILLED

BLIND VIAs

SBU

MECHANICAL DRILLED

BLIND VIAS

SYMBOL

FEATURE

PREFERRED
Producibility Range
mm

REDUCED Producibility  Range mm

 

PREFERRED Producibility Range mm

REDUCED Producibility Range mm

a

Blind via diameter  as formed no plating

125 - 150

100 - 125

³ 250

200

c

Blind via target land size

D = Drilled hole diameter

D + 300

MIN.: 425

D + 200

MIN.: 300