On the following pages, you can find answers to frequently asked questions about printed circuit board technology and related subjects.
In case you do not find the answer to your questions here, please feel free to contact our sales department on telephone +45 7291 2200 or send an e-mail to sales@gpv.dk.
A: The size is determined by the following:
The aspect ratio, i.e. the circuit board thickness divided by the hole diameter, maximum is 8. As an example, the smallest drilled hole that can be used in a circuit board of a thickness of 1.6 mm is: 1.6/8 = 0.2 mm. If the circuit board has a thickness of 2 mm, the smallest drilled hole will be: 2/8 = 0.25 mm.
Minimum pad-size is hole diameter + 0.42 mm on the inner layers, and hole diameter + 0.35 mm on the outer layers.
Minimum drilled hole using mechanical drilling is 0.2 mm.
Other rules apply when using blind/buried laser-drilled vias, please also refer to the HDI section
A: Minimum conductor width is 100 micron on an 18-micron base-copper thickness. On a base-copper thickness of 35 micron, the minimum conductor width would be 125 micron. Correspondingly, the conductor spacing is 100 micron and 125 micron; but in case you should be able to accept a conductor spacing of 125 and 150 respectively, this would improve the manufacturability of the circuit board.
A: The Chemitalic Materials section lists all Chemitalic laminate types and prepregs stating also thickness and dielectric constants.
A: The section Surface Finishes section compares the properties of a selected number of surface finishes.
A: GPVcan handle data from all types of CAD systems, CAD postprocessors and Gerber generators that comply with the following standards:
Layer data: Extended Gerber, RS 274 X (Preferred), Gerber, RS 274 D, IPC-D-350 and IPC-D-356
Routing and drilling data: Extended Gerber RS 274 X, Gerber, RS 274 D, Excellon 1 and Excellon 2 and Sieb & Meyer 1000 and 3000
Drawings: Extended Gerber RS 274 X, Gerber, RS 274 D, HPGL, Autodesk DXF and Adobe PDF
Data compression: .ZIP PKUNZIP (Preferred), .LZH LHA, .ARC PKXARC, .ARJ ARJ, .z Unix compress, .gz Gunzip (Gnu unzip) and .tager Unix Archiving. EXE Self-extracting files to be avoided due to risk of virus infection.
A: Yes, please refer to the Materials section
A: Regarding GPVs standard FR4 laminates and prepregs (Polyclad PCL-FR-226), the following typical values are stated:
|
Laminate thickness < 0.31” (0.78 mm) |
1 MHz |
100 MHz |
1 GHz |
|
Dielectric Constant |
4.6 |
4.5 |
4.3 |
|
Loss tangent |
0.015 |
0.015 |
0.015 |
|
Laminate thickness ³ 0.31” (0.78 mm) |
1 MHz |
100 MHz |
1 GHz |
|
Dielectric Constant |
4.8 |
4.6 |
4.5 |
|
Loss tangent |
0.015 |
0.015 |
0.015 |
A: Yes, but note that galvanic nickel/gold is plated after electroless nickel/gold. This means that auxiliary conductors must be used to establish electrical connection from the galvanic nickel/gold pattern parts to the production panel border material. The auxiliary conductors will be cut in the routing operation.
A: Yes, and there are two options:
The first option is to use auxiliary conductors to establish electrical connection from the galvanic nickel/gold pattern part to the production panel border material; a typical method is to make connection to the edge connectors. The auxiliary conductors will be cut in the routing operation.
The second option is a so-called selective galvanic nickel/gold, which is a process that is carried out prior to the processing of the outer layers' pattern parts; here there is no need for the above auxiliary conductors.
A: The build-up is as follows:
Cu Foil 18 micron
2 X Prepreg 1080
Lamianate 0.1 mm 18/18 micron Cu foil
2 X Prepreg 1080
Lamianate 0.1 mm 18/18 micron Cu foil
2 X Prepreg 1080
Lamianate 0.1 mm 18/18 micron Cu foil
2 X Prepreg 1080
Cu Foil 18 micron
Nominal thickness is 1.00 mm; calculated thickness is 0.964 mm
A: Minimum distance is 0.15 mm in all directions; see FIG 1 below: