Revision 3, July 2004
Please note that a new standard IPC - 2152 : Standard for determining current carrying capacity in Printed Board Design, is in preparation. The information in this document has been prepared for use in determining current carrying capacity and sizes of etched copper conductors for various temperature rises above ambient. It is a tabular version of the graphical information contained in MIL-STD-275E. The notes from this specification are quoted below.
Please note that the maximum current values are for conductors on outer layers, for conductors on inner layers the values shall be reduced by 50%.
|
TEMP. |
Rise °C |
10 |
20 |
30 |
||||||
|
COPPER |
||||||||||
|
oz. |
0,5 |
1 |
2 |
0,5 |
1 |
2 |
0,5 |
1 |
2 | |
|
Micron |
18 |
35 |
70 |
18 |
35 |
70 |
18 |
35 |
70 | |
|
Trace Width Inches |
Trace Width microns |
Maximum Current in Amperes |
||||||||
|
0,0025 |
63,5 |
0,13 |
0,30 |
0,60 |
0,17 |
0,35 |
0,45 |
0,35 |
0,55 |
0,75 |
|
0,005 |
127 |
0,25 |
0,60 |
1,10 |
0,40 |
0,55 |
1,10 |
0,50 |
0,75 |
1,20 |
|
0,010 |
254 |
0,50 |
1,00 |
1,40 |
0,60 |
1,20 |
1,60 |
0,70 |
1,50 |
2,20 |
|
0,015 |
381 |
0,70 |
1,20 |
1,60 |
0,80 |
1,30 |
2,40 |
1,00 |
1,60 |
3,00 |
|
0,020 |
508 |
0,70 |
1,30 |
2,10 |
1,00 |
1,70 |
3,00 |
1,20 |
2,40 |
3,60 |
|
0,025 |
635 |
0,90 |
1,70 |
2,50 |
1,20 |
2,20 |
3,30 |
1,50 |
2,80 |
4,00 |
|
0,030 |
762 |
1,10 |
1,90 |
3,00 |
1,40 |
2,50 |
4,00 |
1,70 |
3,20 |
5,00 |
|
0,050 |
1270 |
1,50 |
2,60 |
4,00 |
2,00 |
3,60 |
6,00 |
2,60 |
4,40 |
7,30 |
|
0,075 |
1905 |
2,00 |
3,50 |
5,70 |
2,80 |
4,50 |
7,80 |
3,50 |
6,00 |
10,00 |
|
0,100 |
2540 |
2,60 |
4,20 |
6,90 |
3,50 |
6,00 |
9,90 |
4,30 |
7,50 |
12,50 |
|
0,200 |
5080 |
4,20 |
7,00 |
11,50 |
6,00 |
10,00 |
11,00 |
7,50 |
13,00 |
20,50 |
|
0,250 |
6350 |
5,00 |
8,30 |
12,30 |
7,20 |
12,30 |
20,00 |
9,00 |
15,00 |
24,5 |